4.1.4 Specific Design Requirements for Sifters
4.1.4.1 Separate conveying air systems shall be provided before and after an atmospheric sifter in the system. To comment or make suggestions regarding this standard or begin a new discussion on this standard click here.
4.1.4.1 Separate conveying air systems shall be provided before and after an atmospheric sifter in the system.
To comment or make suggestions regarding this standard or begin a new discussion on this standard click here.
4.1.4.2 Sifters shall permit continuous discharge of tailings through dust-tight connections to an enclosed container. To comment or make suggestions regarding this standard or begin a new discussion on this standard click here.
4.1.4.2 Sifters shall permit continuous discharge of tailings through dust-tight connections to an enclosed container.
4.1.4.3 Sifters shall employ no rubbing action to facilitate product flow. To comment or make suggestions regarding this standard or begin a new discussion on this standard click here.
4.1.4.3 Sifters shall employ no rubbing action to facilitate product flow.
4.1.4.4 Sifter screen frames shall be designed to prevent replacement in an improper position and shall be readily removable for cleaning To comment or make suggestions regarding this standard or begin a new discussion on this standard click here.
4.1.4.4 Sifter screen frames shall be designed to prevent replacement in an improper position and shall be readily removable for cleaning
4.1.4.5 Sifter screens shall be minimum mesh to allow passage of product. To comment or make suggestions regarding this standard or begin a new discussion on this standard click here.