ANSI/BISSC/Z50.2-2003 Sanitation Standard

 

4.36 DESIGN REQUIREMENTS FOR PARTICLE SIZE REDUCTION EQUIPMENT

4.36.1 Specific Design Requirements

4.36.1.1 Reducing mechanisms, such as knives, blades, hammers, etc., shall be accessible or removable for cleaning.

To comment or make suggestions regarding this standard or begin a new discussion on this standard click here

4.36.1.2 Reducing mechanism hubs and spacing collars shall have matching diameters and faces to afford a tight fit and to eliminate the formation of shoulders. Setscrews shall not be used. Exposed keys, keyways or splines shall not be used in the product zone.

To comment or make suggestions regarding this standard or begin a new discussion on this standard click here

4.36.1.3 Shaft seal assemblies and seal rings shall be both readily accessible and readily retractable, or shall be readily removable for cleaning.

To comment or make suggestions regarding this standard or begin a new discussion on this standard click here

4.36.1.4 Bearings in the product zone shall be self-lubricating and readily removable. All surfaces shall be readily accessible for cleaning.

To comment or make suggestions regarding this standard or begin a new discussion on this standard click here

4.36.1.5 Augers or other pre-feed devices shall be accessible or removable for cleaning.

To comment or make suggestions regarding this standard or begin a new discussion on this standard click here

 

Created August 2006 - American Society of Baking