ANSI/BISSC/Z50.2-2003
Sanitation Standard
|
|
4.3 DESIGN REQUIREMENTS
FOR MECHANICAL INTERMEDIATE PROOFERS
|
|
|
4.3.1 Definitions
|
|
|
4.3.1.1 Proofing: That
operation where the dough pieces, after fermentation and/or dividing
into suitably sized sections, are allowed to "rest" and
regain the proper dough condition for moulding or other make-up
in the baking process.
To
comment or make suggestions regarding this standard or begin
a new discussion on this standard click here.
|
|
|
4.3.1.2 Intermediate
Proofer: That enclosure, cabinet, machine or device in which
dough pieces are allowed to regain their proper condition for
make-up, and includes all belts, trays, housing structural supports,
motors, chains, and loading, driving and discharge mechanisms
used to accomplish the proofing process.
To
comment or make suggestions regarding this standard or begin
a new discussion on this standard click here.
|
|
|
4.3.2 Specific Design
Requirements
|
|
|
4.3.2.1 All internal
and external framework, bumpers, guides, tracks or supports resting
on floors or attached to ceiling or walls shall be sealed at
the point of contact, and supports and braces, if hollow, shall
be sealed. All components shall be easily accessible for thorough
cleaning.
To
comment or make suggestions regarding this standard or begin
a new discussion on this standard click here.
|
|
|
4.3.2.2 External hinges,
attachment mechanisms and latches for holding inspection doors,
port covers, access doors and other detachable parts shall be
of the simple take-apart type.
To
comment or make suggestions regarding this standard or begin
a new discussion on this standard click here.
|
|
|
4.3.2.3 Base of the
proofer unit, except for vertical support members, shall have
a minimum clearance of 6 inches (150mm) above the floor.
To
comment or make suggestions regarding this standard or begin
a new discussion on this standard click here.
|
|
|
4.3.2.4 Catch pans under
any section of the proofer shall be readily removable and shall
not rest directly on the floor.
To
comment or make suggestions regarding this standard or begin
a new discussion on this standard click here.
|
|
|
4.3.2.5 Top of proofer
housing shall be so designed that flour or dust cannot sift down
into the product zone or mechanism.
To
comment or make suggestions regarding this standard or begin
a new discussion on this standard click here.
|
|
|
4.3.2.6 Trays shall
be readily removable or readily accessible for thorough cleaning.
To
comment or make suggestions regarding this standard or begin
a new discussion on this standard click here.
|
|
|
4.3.2.7 Fabric linings
for trays shall be readily removable.
To
comment or make suggestions regarding this standard or begin
a new discussion on this standard click here.
|
|
|
4.3.2.8 Trays should
not be hollow, but if hollow, shall be constructed of durable
and shatterproof material, and sealed.
To
comment or make suggestions regarding this standard or begin
a new discussion on this standard click here.
|
|
|
4.3.2.9 Proofer sprockets,
chains and other mechanisms shall be accessible and shall be
so constructed and located that lubricant cannot leak, drip or
be forced into the product zone.
To
comment or make suggestions regarding this standard or begin
a new discussion on this standard click here.
|
|
|
4.3.2.10 Discharge conveyor
housings shall be removable and accessible for cleaning.
To
comment or make suggestions regarding this standard or begin
a new discussion on this standard click here.
|
Created