ANSI/BISSC/Z50.2-2003
Sanitation Standard
|
|
4.12. DESIGN REQUIREMENTS FOR COATING EQUIPMENT
|
|
|
4.12.1 Definitions
|
|
|
4.12.1.1 The product zone, as defined in Section 2.11, shall include
all surfaces, including bottoms, with which ingredients used in
the coating of food products in normal production may have contact,
magazines, entry pipes, fittings, pumps, agitators, blowers, and
those surfaces over or through which forced flows of air are directly
applied to the product, conveyor belts and such adjuncts as side
guards, fittings, carrying rollers, and devices with which the
coating and other food products may have direct or indirect contact
during the process of drying and cooling, and the interior surfaces
of cooling and drying tunnels, housings and ducts therein over
or through which forced flows of air are directly applied to the
food product.
To
comment or make suggestions regarding this standard or begin
a new discussion on this standard click here.
|
|
|
4.12.2 Specific Design Requirements
|
|
|
4.12.2.1 Openings for the introduction of coating and ingredients
shall be designed so as to prevent spillage. Covers shall be provided
for such ingredient openings and shall be removable, easy to clean
and equipped with a means of protection against the entry of foreign
material from the exterior of the cover. Such openings shall have
a raised rim of at least 3/8 inch (10mm).
To
comment or make suggestions regarding this standard or begin
a new discussion on this standard click here.
|
|
|
4.12.2.2 The coating reservoir shall be accessible without cutting
the conveyor belt or dismantling the conveyor and easily accessible
for cleaning.
To
comment or make suggestions regarding this standard or begin
a new discussion on this standard click here.
|
|
|
4.12.2.3 The coating reservoir shall be self-draining.
To
comment or make suggestions regarding this standard or begin
a new discussion on this standard click here.
|
|
|
4.12.2.4 Air ducts and baffles for the delivery and distribution
of air shall comply with Section 3.1
To
comment or make suggestions regarding this standard or begin
a new discussion on this standard click here.
|
|
|
4.12.2.5 Blowers, which remove coatings from food product, shall
be readily accessible and shall comply with Section 3.1.
To
comment or make suggestions regarding this standard or begin
a new discussion on this standard click here.
|
|
|
4.12.2.6 Blower intake hoods shall be readily removable. Blower
blades, motor mounts, and related parts shall be readily accessible.
To
comment or make suggestions regarding this standard or begin
a new discussion on this standard click here.
|
|
|
4.12.2.7 Air distribution horn or cone shall be removable. Horn
or cone adjustments shall be readily accessible and removable.
To
comment or make suggestions regarding this standard or begin
a new discussion on this standard click here.
|
|
|
4.12.2.8 Wire belt rollers shall be readily accessible.
To
comment or make suggestions regarding this standard or begin
a new discussion on this standard click here.
|
|
|
4.12.2.10 Heater units installed under a coating return section
shall be readily accessible.
To
comment or make suggestions regarding this standard or begin
a new discussion on this standard click here.
|
|
|
4.12.2.11 Product conveying surfaces shall be readily accessible
and removable, and shall be designed for minimum product retention
and complete cleaning.
To
comment or make suggestions regarding this standard or begin
a new discussion on this standard click here.
|
|
|
4.12.2.12 Attachments used to prevent accumulations on aprons
or belts shall be readily accessible and removable.
To
comment or make suggestions regarding this standard or begin
a new discussion on this standard click here.
|
|
|
4.12.2.13 Readily removable drip or catch pans shall be provided
under cleaning attachments and transfer points.
To
comment or make suggestions regarding this standard or begin
a new discussion on this standard click here.
|
|
|
4.12.2.14 Sensing devices used in the product zone shall be suitable
for the application and shall have shatter-resistant faces.
To
comment or make suggestions regarding this standard or begin
a new discussion on this standard click here.
|
|
|
4.12.2.15 Pumps, valves, pipes and fittings, including those used
to insert sensing bulbs, except those which are normally continuously
filled, shall be of the sanitary take-apart type and shall be readily
accessible or readily removable.
To
comment or make suggestions regarding this standard or begin
a new discussion on this standard click here.
|
|
|
4.12.2.16 All devices, including the mounting brackets, used for
the purpose of stacking, shingling or otherwise aligning the food
products prior to packing, shall comply with Section 3.1.
To
comment or make suggestions regarding this standard or begin
a new discussion on this standard click here.
|
|
|
4.12.2.17 Enclosure panels shall be smooth and readily removable
for cleaning.
To
comment or make suggestions regarding this standard or begin
a new discussion on this standard click here.
|
|
|
4.12.2.18 Insulation within doors or access panels shall be isolated
by sealing the fabricated joint or seam of the door or access panel.
When multiple insulated panels are used (as in tunnel walls or
tops), insulations shall be isolated within each individual panel
by sealing.
To
comment or make suggestions regarding this standard or begin
a new discussion on this standard click here.
|
|
|
4.12.2.19 Shaft seal rings shall be readily accessible and readily
removable or retractable, to permit cleaning of all product zone
surfaces thereon, including the face of the agitator hub.
To
comment or make suggestions regarding this standard or begin
a new discussion on this standard click here.
|
|
|
4.12.2.20 Take-up rollers and their bearings shall be removable.
To
comment or make suggestions regarding this standard or begin
a new discussion on this standard click here.
|
|
|
4.12.2.21 Rollers, pulleys, sprockets and wheels shall be free
of end recesses. Sprockets and wheels in the product zone shall
be solid disks.
To
comment or make suggestions regarding this standard or begin
a new discussion on this standard click here.
|
|
|
4.12.2.22 Electrical, plumbing and sensing device lines shall
be grouped and protected by seal enclosures.
To
comment or make suggestions regarding this standard or begin
a new discussion on this standard click here.
|
|
|
4.12.2.23 Cooling coils shall be readily accessible and easily
cleanable.
To
comment or make suggestions regarding this standard or begin
a new discussion on this standard click here.
|
|
|
4.12.2.24 A minimum space of 8 inches (200mm) shall be provided
between the floor and the bottom of the coater.
To
comment or make suggestions regarding this standard or begin
a new discussion on this standard click here.
|
|
|
4.12.2.25 A minimum space of 12 inches (300mm) shall be provided
between the floor and the bottom of the frame and body of the conveyor.
To
comment or make suggestions regarding this standard or begin
a new discussion on this standard click here.
|
|
|
4.12.2.26 Bunker boxes and other refrigeration or heating equipment
used under processing conveyors shall have condensate drainage,
and the drainage pans shall be designed so as to prevent entry
to food products. A minimum space of 6 inches (150mm) shall be
provided between the floor and bunker boxes or related equipment.
To
comment or make suggestions regarding this standard or begin
a new discussion on this standard click here.
|
Created