ANSI/BISSC/Z50.2-2003 Sanitation Standard

4.12. DESIGN REQUIREMENTS FOR COATING EQUIPMENT

4.12.1 Definitions

4.12.1.1 The product zone, as defined in Section 2.11, shall include all surfaces, including bottoms, with which ingredients used in the coating of food products in normal production may have contact, magazines, entry pipes, fittings, pumps, agitators, blowers, and those surfaces over or through which forced flows of air are directly applied to the product, conveyor belts and such adjuncts as side guards, fittings, carrying rollers, and devices with which the coating and other food products may have direct or indirect contact during the process of drying and cooling, and the interior surfaces of cooling and drying tunnels, housings and ducts therein over or through which forced flows of air are directly applied to the food product.

To comment or make suggestions regarding this standard or begin a new discussion on this standard click here.

4.12.2 Specific Design Requirements

4.12.2.1 Openings for the introduction of coating and ingredients shall be designed so as to prevent spillage. Covers shall be provided for such ingredient openings and shall be removable, easy to clean and equipped with a means of protection against the entry of foreign material from the exterior of the cover. Such openings shall have a raised rim of at least 3/8 inch (10mm).

To comment or make suggestions regarding this standard or begin a new discussion on this standard click here.

4.12.2.2 The coating reservoir shall be accessible without cutting the conveyor belt or dismantling the conveyor and easily accessible for cleaning.

To comment or make suggestions regarding this standard or begin a new discussion on this standard click here.

4.12.2.3 The coating reservoir shall be self-draining.

To comment or make suggestions regarding this standard or begin a new discussion on this standard click here.

4.12.2.4 Air ducts and baffles for the delivery and distribution of air shall comply with Section 3.1

To comment or make suggestions regarding this standard or begin a new discussion on this standard click here.

4.12.2.5 Blowers, which remove coatings from food product, shall be readily accessible and shall comply with Section 3.1.

To comment or make suggestions regarding this standard or begin a new discussion on this standard click here.

4.12.2.6 Blower intake hoods shall be readily removable. Blower blades, motor mounts, and related parts shall be readily accessible.

To comment or make suggestions regarding this standard or begin a new discussion on this standard click here.

4.12.2.7 Air distribution horn or cone shall be removable. Horn or cone adjustments shall be readily accessible and removable.

To comment or make suggestions regarding this standard or begin a new discussion on this standard click here.

4.12.2.8 Wire belt rollers shall be readily accessible.

To comment or make suggestions regarding this standard or begin a new discussion on this standard click here.

4.12.2.10 Heater units installed under a coating return section shall be readily accessible.

To comment or make suggestions regarding this standard or begin a new discussion on this standard click here.

4.12.2.11 Product conveying surfaces shall be readily accessible and removable, and shall be designed for minimum product retention and complete cleaning.

To comment or make suggestions regarding this standard or begin a new discussion on this standard click here.

4.12.2.12 Attachments used to prevent accumulations on aprons or belts shall be readily accessible and removable.

To comment or make suggestions regarding this standard or begin a new discussion on this standard click here.

4.12.2.13 Readily removable drip or catch pans shall be provided under cleaning attachments and transfer points.

To comment or make suggestions regarding this standard or begin a new discussion on this standard click here.

4.12.2.14 Sensing devices used in the product zone shall be suitable for the application and shall have shatter-resistant faces.

To comment or make suggestions regarding this standard or begin a new discussion on this standard click here.

4.12.2.15 Pumps, valves, pipes and fittings, including those used to insert sensing bulbs, except those which are normally continuously filled, shall be of the sanitary take-apart type and shall be readily accessible or readily removable.

To comment or make suggestions regarding this standard or begin a new discussion on this standard click here.

4.12.2.16 All devices, including the mounting brackets, used for the purpose of stacking, shingling or otherwise aligning the food products prior to packing, shall comply with Section 3.1.

To comment or make suggestions regarding this standard or begin a new discussion on this standard click here.

4.12.2.17 Enclosure panels shall be smooth and readily removable for cleaning.

To comment or make suggestions regarding this standard or begin a new discussion on this standard click here.

4.12.2.18 Insulation within doors or access panels shall be isolated by sealing the fabricated joint or seam of the door or access panel. When multiple insulated panels are used (as in tunnel walls or tops), insulations shall be isolated within each individual panel by sealing.

To comment or make suggestions regarding this standard or begin a new discussion on this standard click here.

4.12.2.19 Shaft seal rings shall be readily accessible and readily removable or retractable, to permit cleaning of all product zone surfaces thereon, including the face of the agitator hub.

To comment or make suggestions regarding this standard or begin a new discussion on this standard click here.

4.12.2.20 Take-up rollers and their bearings shall be removable.

To comment or make suggestions regarding this standard or begin a new discussion on this standard click here.

4.12.2.21 Rollers, pulleys, sprockets and wheels shall be free of end recesses. Sprockets and wheels in the product zone shall be solid disks.

To comment or make suggestions regarding this standard or begin a new discussion on this standard click here.

4.12.2.22 Electrical, plumbing and sensing device lines shall be grouped and protected by seal enclosures.

To comment or make suggestions regarding this standard or begin a new discussion on this standard click here.

4.12.2.23 Cooling coils shall be readily accessible and easily cleanable.

To comment or make suggestions regarding this standard or begin a new discussion on this standard click here.

4.12.2.24 A minimum space of 8 inches (200mm) shall be provided between the floor and the bottom of the coater.

To comment or make suggestions regarding this standard or begin a new discussion on this standard click here.

4.12.2.25 A minimum space of 12 inches (300mm) shall be provided between the floor and the bottom of the frame and body of the conveyor.

To comment or make suggestions regarding this standard or begin a new discussion on this standard click here.

4.12.2.26 Bunker boxes and other refrigeration or heating equipment used under processing conveyors shall have condensate drainage, and the drainage pans shall be designed so as to prevent entry to food products. A minimum space of 6 inches (150mm) shall be provided between the floor and bunker boxes or related equipment.

To comment or make suggestions regarding this standard or begin a new discussion on this standard click here.

 

Created August 2006 - American Society of Baking